The duct size is directly proportional to the cfm rating.
Kitchen ventilation fan size. Static pressure in fan systems is typically less than 2 sp or 0 072 psi. What size cfm remote kitchen exhaust fan should i use to properly vent a 4 burner gas cooktop. Whisperceiling dc precision spot ventilation fan with built in pick a flow speed selector switch allows you to select your required airflow 50 80 110 cfm. Read on to determine how to size your exhaust and supply fans.
A range hood should exchange the air in the kitchen 15 x per hour. Note that not both exhaust fans are required for hood exhaust. One pound per square inch is equivalent to 27 7 sp. A pressure differential between the duct and the.
The size shape length turns and cap on the range hood ductwork adds resistance which reduces the amount of air the vent fan can move requiring additional cfm for the fan. Whisperceiling dc precision spot ventilation fan with built in pick a flow speed selector. The minimum allowed fan size is 50 cfm so if your bathroom is for example only 42 square feet you still need a 50 cfm fan. The distance from the exhaust above the stove to fan on the outside wall is 14 feet and there are 3 x 90 degree bends to get to the outer wall to vent.
Features a ecm motor with smar. Whisperceiling dc smartflow 110 130 150. The exhaust fan drawing below illustrates how static pressures are measured in ductwork with a manometer. For bathrooms over 100 square feet exhaust fans can be sized according to the number of fixtures in the room.
Our extensive range has got you covered with products available in a range of styles and colours to suit all room sizes and locations the right extractor will help to prevent unwanted steam from lingering and to help avoid damp problems. Sizing for large bathrooms. To find the size of fan needed multiply the cubic feet x the of air exchanges 15 then divide by 60 minutes in an hour. To calculate using this formula add up the required cfm ratings for all of the.
When using smooth round 8 diameter metal pipe add one cfm per foot of pipe plus 25 cfm for each elbow and 40 cfm for a roof cap. The illustration above shows a typical commercial kitchen application utilizing a roof mount upblast exhaust fan or wall mount upblast exhaust fan in conjunction with a supply fan. The cubic feet per minute rating is a measure of how much air the fan can exhaust from the kitchen in a minutes time. All you need to do is select the application from the dropdown enter the size of the room and we will provide you with a general capacity range m3 hr that you should be looking to achieve from the extraction fan.
If your kitchen is 12 x 15 and 10 high that equals 1 800 cubic feet. An extractor fan is excellent at helping to help remove moisture and unwanted odours from your home or office.